A Vitamin-D deficiency is a global health issue and is one of the most common nutrient deficiencies. India gets surplus sun, yet a large percentage of Indians suffer from significant vitamin D deficiency. More than seven out of ten Indians lack in vitamins, and most of them suffer from vitamin D deficiency. The prevalence of Vitamin D deficiency in India ranged from 40% to 99%, with most of the studies reporting a prevalence of 80%–90%.It is prevalent in all the age groups and high-risk groups alike.

Ultraviolet B Radiation

Vitamin D is produced by skin exposed to ultraviolet B radiation or obtained from dietary sources, including supplements.Persons commonly at risk for vitamin D deficiency include those with inadequate sun exposure, limited oral intake, or impaired intestinal absorption.

 

Vitamin Disorder

Vitamin-D deficiency has been associated with rickets, osteomalacia, osteoporosis, as well as fetal development, immune system function, neurological disorder such as multiple sclerosis,cancer, and many other pathologies.

 

Diagnosis & Montioring – 25 HYDROXYVITA D (25-Hydroxyvitamin D Concentration in the blood)

Measuring accurate level of Vitamin- D in patients is very important for the diagnosis of Vitamin-D deficiency and for the monitoring of deficient patients to achieve optimal levels.Vitamin D adequacy is best determined by measurement of the 25-hydroxyvitamin D concentration in the blood.

 

Test In Market:ELISA),

chemiluminescence immunoassay and protein binding assays are used in routine testing of 25(OH)D in clinical laboratories. LCTMS (liquid chromatography tandem mass spectrometry) is the widely accepted reference method for 25(OH)D measurement. However, LCTMS is tedious, expensiveand time consuming and therefore seldom used commercially.

 

ELISA Kit

 

ELISA method is commonly used to quantify the 25-hydroxyvitamin D

concentration in the blood in clinical laboratories.

 

TRUSTwell – Vitamin D (Total) ELISA Kit can quantify total 25(OH) Vitamin D

in human serum and comes with the following perks & benefits to the customers.

_ Accuracy : R2 = 0.918 with CLIA as reference

_ Analytical Sensitivity: 1.2 ng/mL

_ Specificity: No cross reactivity to non-hydroxylated vitamin D2 and Vitamin D3

_ Calibrator range: 0-150 ng/mL

_ Intra & Inter assay precision : CV <=10%

_ Higher linearity: 0-150 ng/mL

_ 1 step less procedure, faster resulting

_ High & Low level assay controls